Building Heat Loss Calculator
Calculate a building heat loss coefficient from element areas and U-values, then the peak heating load and annual heat demand.
Are you a real estate agent or broker? Put this calculator on your own agent page, beside your listings, so the buyer who ran the numbers can message you in one tap. Create free agent page →
Heat loss is the number behind almost every energy decision in a building. It sizes the heating system, it determines the annual fuel bill, and the change in it is what any insulation upgrade is actually buying.
The calculation is a sum of areas multiplied by U-values, plus ventilation. A U-value is the heat lost per square metre per degree of temperature difference, so a lower number is better — modern walls are around 0.2 and uninsulated solid walls above 1.5.
The calculation
Heat loss coefficient = the sum of each element area × its U-value, plus ventilation losses, giving watts lost per degree of temperature difference. Peak load = coefficient × design temperature difference. Annual demand = coefficient × degree days × 24 ÷ 1000, which converts to kilowatt hours.
Worked example
Walls of 120 at 1.5 lose 180 W/K, a 60 roof at 0.4 loses 24, a 60 floor at 0.7 loses 42 and 20 of glazing at 2.8 loses 56 — 302 W/K of fabric loss. Adding 50 W/K of ventilation gives 352 W/K. At a 23 K design difference the peak load is 8.1 kW, and across 2,500 degree days the annual heat demand is about 21,120 kWh.
Where to spend on insulation
The elements losing the most are where money works hardest. Here the walls lose 180 W/K on their own — more than everything else combined — so wall insulation dominates any retrofit, while replacing the already-decent roof insulation would barely register.
Put your number on the page that answers the question
Buyers remember whoever gave them the answer. A property page of your own carries this calculator, your listings and a WhatsApp button, so the next question comes to you.
Create your free property pageFrequently asked questions
What is a U-value?
The heat lost through a square metre of an element for each degree of temperature difference, in watts. Lower is better: modern insulated walls are around 0.18 to 0.30, while uninsulated solid walls are frequently above 1.5.
Where do degree days come from?
They are published for most regions and measure how far and for how long outdoor temperature falls below a base level across a year. Using the figure for your own location is essential, since climates vary by a factor of several.
Does this size a heat pump correctly?
It gives a defensible peak load, which is the starting point, but a heat pump also needs flow temperature, emitter sizing and hot water demand considered. Use this to sanity-check a quote, not to replace a proper design.
More development calculators
Energy upgrade payback
How long an efficiency upgrade takes to pay for itself.
OwningHeating cost comparison
Which heating system actually costs less to run.
OwningSolar payback
What solar saves, and when it pays for itself.
DevelopmentResidual land value
The most a site is worth once everything is paid for.
DevelopmentBuild cost estimate
The construction budget, not just the builder quote.
DevelopmentFloor area ratio
How much floor space a plot actually permits.
DevelopmentConstruction finance cost
What funding a build actually costs before it sells.
DevelopmentLand holding cost
What holding land through planning really costs.
DevelopmentDemolition cost
Clearing the site, including what the quote omits.
DevelopmentPlanning application cost
What an application costs before any decision.
DevelopmentParty wall cost
What notifiable works cost in surveyor fees.
DevelopmentScaffolding cost
Erection, hire by the week, and the permit.